Description
Professionals looking for a product with the highest possible mold resistant rating should look no further. IAQ 6000 GEN3 is uniquely formulated to resist mold growth on the dry coating surface, recommended for use on a multitude of surfaces and on new structural materials during building construction.
*Resists mold on the dry coating surface only
How to Use
SURFACE PREPARATION
Surfaces to be coated must be free of dust, dirt, grease, loose paint, oil, glue size, calcimine, wax, soap and other surface contamination. Clean mold stained surfaces with IAQ Advanced Peroxide Cleaner, or use an EPA registered antimicrobial disinfectant cleaner such as IAQ 2000, IAQ 2500, ShockWave or ShockWave RTU. Patch irregularities with vinyl patching paste or an appropriate patching compound. IAQ 6000 GEN3 is self-priming over bare sheetrock, composition board, ceiling tile and concrete.
WALLBOARD, SHEETROCK, GYPSUM BOARD
Joint cement should be sanded smooth, but avoid abrading the paper.
FERROUS METAL
Clean, then prime with IAQ 4000 rust inhibiting direct-to-metal primer.
WOOD
Seal knots and stains with IAQ 5000 stain blocking primer.
MASONRY BLOCK
Apply one coat of IAQ 3000 block filler if a denser surface is desired.
APPLICATION TOOLS
Apply IAQ 6000 GEN3 with a brush, roller or airless spray equipment.
Brush: Synthetic, nylon or polyester bristle
Roller: Synthetic fiber 3/8” nap or longer
Spray Settings: Pressure: 2000-3000 P.S.I. Tips: .019 to .021 tips
TINTING
IAQ 6000 GEN3 may be tinted to any off-white or pastel based color. Add up to 2 oz. of universal colorant per gallon. Start with 50% of the tinting formula and adjust as necessary.
PRODUCT APPLICATION
IAQ 6000 GEN3 is supplied ready to use, but can be thinned sparingly with water (up to 1/2 pint water per gallon) for proper application consistency if necessary. Apply IAQ 6000 GEN3 generously and uniformly by brush, roller, or airless spray. Apply one coat of IAQ 6000 GEN3 and ensure that the finished surface is properly sealed. To ensure that the finished surface is properly sealed, two-coats may be required on some porous surfaces.
COVERAGE
Smooth Surfaces- 250-400 sq. ft. per gallon
Porous Surfaces- 150-300 sq. ft. per gallon
CLEANUP
Clean tools and drippings with warm soapy water before IAQ 6000 GEN3 dries. Dispose of waste according to all existing local, state and federal regulations.
PRECAUTIONS
Store in a dry place at temperatures between 40°F (4.5°C) and 90°F. (32°C). Stir thoroughly. Do not mix with any other coatings, solvents or colors in oil. The IAQ 6000 GEN3 coating is resistant to mold only on the surface of the coating. No mold resistance claim is made other than to the coating itself. The use of this product does not protect users or others against food-borne or disease-causing bacteria, viruses, germs or other disease-causing organisms. Do not apply when air or surface temperature is below 50°F (10°C), or when drying conditions are poor or when surfaces are above a 15% moisture level content. Use adequate ventilation during application. When applying with a sprayer, wear a NIOSH approved respirator with any R, P, N or HE filter. For interior use only.